Circutor DISPENSER Series Manual de usuario Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 124
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
Figure 54:Create a new tariff (Energy blocks)
Table 17:Create a new tariff (Energy blocks)
Denition of conditions
Parameter Description Range of values
Default
values
Period
Energy block operating period. When the period is
about to end, the energy meter resets the value of
consumed energy to start consuming from Block
1.
Day, Week, Month Day
Block 1, 2 and 3
Price factor Energy price factor
Block 1 and 2 :
0���5
Block 3: 0���65
0
Block 1 and 2
Energy
Consumption of energy after which the system
skips to a different block.
0���65 kWh 0
6�- Advanced
The end of the contract validity period is congured in the Advanced window, Figure 55.
Figure 55:Create a new tariff (Advanced Mode)