Circutor AFQ Series Manual de usuario Pagina 82

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 106
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 81
AFQ-4W
82 Instruction Manual
battery. If the board has jumpers, move the two jumpers closest to the battery. If
the initial status was “0000”, now it should be “0011”. (Figure 93)
Figure 93: Change the position of the jumpers (A) or micro switches (B)
5.- Connect the memory stick supplied by CIRCUTOR to port J12 next to the
micro-switches or jumpers.
It should be connected with the fat side facing the battery. (Figure 94)
Figure 94: Connect the memory stick to port J12
6.- Close the filter door and power it up.
7.- Wait 2 minutes and turn off the AFQ-4W once more. The updating process
should have finished.
8.- Turn off the unit and wait 5 minutes for the energy accumulated in the
capacitors to discharge.
9.- Open the filter door.
10.- Disconnect the memory stick.
11.-Change the position of the micro-switches or the jumpers to the initial
configuration “0000”.
12.- Fit the protection board.
Vista de pagina 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 105 106

Comentarios a estos manuales

Sin comentarios