INSTRUCTION MANUAL(M98252701-03-14A)Protocol transducerCMBUS-8 CMBUS-24
3.4.- CONNECTION DIAGRAMAUX. Supply24 V CCL+M-MBUS-MBUS+B(-)A(+)MODBUSTxRxRS-232M-BUS 1M-BUS nMBUS-MBUS-MBUS+MBUS+GNDFigure 5:Connection diagra
4�- START-UPThe initial conguration of the unit is complete using the 4 MiniDips found on the front panel of the unit.MiniDipsFigure 6: Location of
5�- OPERATIONThe M-BUS protocol (Meter-Bus) is a communications bus used to read information from gas, water and energy meters. M-BUS is a hierarchic
AUX. Supply24V CCL+M-M-BUSMODBUSTxRxRS-232Tx(3)Rx(2)Figure 7: CMBUS connection to the RS-232 port5�- Connect the CMBUS to the power supply.6�- Put the
Figure 9:Selecting “Scan serial ports for device”�10�- Once the COM port has been detected, you can add a CMBUS unit to the project by clicking on the
5�2�2�- ADDING M-BUS UNITS FROM THE DATABASEYou can add the M-BUS units connected to the CMBUS from the database by following these steps:1�- Click on
Figure 13: M-BUS slave unit added to the project5�2�3� ADDING M-BUS UNITS THROUGH AUTO-DETECTIONYou can also add M-BUS units through auto-detection by
The auto-detection process can take between 1 and 15 minutes. You can see the progress of the search process on the bar at the bottom of the program s
5�2�4� CMBUS START-UPOnce the slave units and their corresponding M-BUS memory maps have been determined, and the Modbus parameters to which the conve
If you need to restart the project again, it is important to send the unit an empty conguration without congured M-BUS slave units. This process wil
2CMBUSInstruction Manual
6�- TECHNICAL FEATURESPower supplyRated voltage 18 V ... 30 V Typical consumption 36 mAMaximum consumption (operating) 55 mAMaximum consumption (star
Figure 20: Dimensions of the CMBUSStandardsLow voltage directive LVD 73/23/EECElectromagnetic compatibility EMC 89/336/EECCE Marking CE 93/68/EECEmis
7�- MAINTENANCE AND TECHNICAL SERVICEIn the case of any query in relation to unit operation or malfunction, please contact the CIRCUTOR, SA Technical
9�- CE CERTIFICATE23Instruction ManualCMBUS
CIRCUTOR, SA Vial Sant Jordi, s/n08232 -Viladecavalls (Barcelona)Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circutor.
SAFETY PRECAUTIONS DISCLAIMERCIRCUTOR, SA reserves the right to make modi cations to the device or the unit speci ca-tions set out in this instruct
CONTENTSSAFETY PRECAUTIONS ��������������������������������������������������������������������������������������������������������������������������
REVISION LOGTable 1: Revision log�Date Revision Description09/14 M98252701-03-14A Initial VersionNote: The images of the units are for illustrative p
1�- VERIFICATION UPON RECEPTIONCheck the following points when you receive the unit: a) The unit meets the specications described in your order. b
3�- UNIT INSTALLATION3.1.- PRELIMINARY RECOMMENDATIONSIn order to use the unit safely, it is critical that individuals who handle it follow the safet
Figure 2: Installing the CMBUS on a DIN railTo uninstall from the DIN rail (Figure 3): 1�- Pull the clip downwards. 2�- Pull the unit to release the
3.3.- UNIT TERMINALSTable 2: List of unit terminals�Terminal DescriptionA A (+) ModbusB B (-) ModbusL+ + 24 VdcM- GNDRx RS-232, data reception T