40
The value placed In two suc-
cessive 16-bit registers. These
registers include the same data as
32-bit registers from the area 7500
The value is placed in 32-bit
registers
Name
Write
(w)
/
rea-
dout
(r)
Unit Name of the quantity
7000 7500 Identifier O —
Constant identifying the device.
The value 187 means the DHB-224
7002 7501 Status O —
Status is register describing the current
state of the meter
7004 7502 Control O %
It is a register defining the control of the
analog outpu
7006 7503 Minimum O —
Minimal value of the currently displayed
value
7008 7504 Maximum O —
Maximal value of the currently dis-
played value
7010 7505
Displayed
value
O — Currently displayed value
7012 7506 O — Current time
7014 7507 O Reserved
7016 7508 O —
Password of analog-to-digital trans-
ducer
7018 7509 O Reserved
7020 7510 O
Measured value – not recalculated
In relation to the individual characteristic,
a.s.l.
7022 7511 O Reserved
7024 7512 O Reserved
6.6. Registers only for Readout
Table 11