Circutor ReadWatt Series Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Instrumentos de medición Circutor ReadWatt Series. CIRCUTOR ReadWatt Series User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
INSTRUCTION MANUAL
(M018B01-03-14B)
Impulse sensor
ReadWatt
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL(M018B01-03-14B)Impulse sensorReadWatt

Pagina 2

3.3.- UNIT TERMINALSThe unit has a RJ45 connector with the following list of terminals (Table 2):Table 2:List of ReadWatt terminals�Unit terminals1:

Pagina 3

3.4.- CONNECTION DIAGRAM3�4�1�- RS-485 CONNECTIONUse an intelligent RS-232 to RS-485 network protocol converter to establish the com

Pagina 4

3�4�2�- PULSE OUTPUT CONNECTION+VCC76IN76COMMON+VCCRABFigure 7: Pulse Output connection�12ReadWattInstruction Manual

Pagina 5 - REVISION LOG

4�- OPERATION ReadWatt reads the light impulses from the meter, whose value is shown in real time on a MODBUS parameter, which can be queried by anot

Pagina 6

4.3- COMMUNICATIONSReadWatt has two communications ports, RS-232 and RS-485. Both ports can be used simul-taneously.The transmission speed, Baudra

Pagina 7

4�3�3�- WRITE COMMANDSReadWatt supports the integer type write functions: 0x10. The unit's MODBUS variables are specied in Table 4.Example:

Pagina 8 - Figure 2)

(1)Transformation ratio:The pulses generated by a billing meter are always associated to the secondary, so that the Conversion Ratio (Transformation R

Pagina 9

AddressFunc-tionInitial log Log no� No� bytes Unit serial no� Data CRC00 10 0BBA 0001 02 SSSS SSSS DDDD CRCNote: The serial number must be hexadecima

Pagina 10 - 3.3.- UNIT TERMINALS

5�- TECHNICAL FEATURESPower supplyRated voltage5 V ... 24 V Tolerance ± 5%Consumption < 0.5 WMemory Setup, logs EEPROM and FRAM type non-volatil

Pagina 11 - ReadWatt

32.1525.6Figure 10: ReadWatt dimensions 19Instruction ManualReadWatt

Pagina 12

2ReadWattInstruction Manual

Pagina 13 - Table 3

6�- MAINTENANCE AND TECHNICAL SERVICE 7�- GUARANTEE• No returns will be accepted and no unit will be repaired or replaced if it is not ac-companied b

Pagina 14 - Table 4

8�- CE CERTIFICATE21Instruction ManualReadWatt

Pagina 15

CIRCUTOR, SA Vial Sant Jordi, s/n08232 -Viladecavalls (Barcelona)Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circuto

Pagina 16 - Serie no

SAFETY PRECAUTIONS DISCLAIMERCIRCUTOR, SA reserves the right to make modi cations to the device or the unit speci ca-tions set out in this instruct

Pagina 17 - Table 5

CONTENTS SAFETY PRECAUTIONS �����������������������������������������������������������������������������������������������������3 DISCLAIMER �

Pagina 18 - 5�- TECHNICAL FEATURES

REVISION LOGTable 1: Revision log�Date Revision Description03/14 M018B01-03-14A Initial Version04/14 M018B01-03-14B Changes : Points 3.4, 4.3.4 and

Pagina 19 -

1�- VERIFICATION UPON RECEPTIONCheck the following points when you receive the unit: a) The unit meets the specications described in your order.

Pagina 20

3�- UNIT INSTALLATION 3.1.- PRIOR RECOMMENDATIONSIn order to use the unit safely, it is critical that individuals who handle it follow the safe

Pagina 21 - 8�- CE CERTIFICATE

3.2.- INSTALLATIONThe unit is installed on the energy meter.The rst step for installing ReadWatt is to separate the two parts of the Velcro st

Pagina 22 - Vial Sant Jordi, s/n

Now simply place the ReadWatt on the energy meter's Velcro strap (Figure 3). Figure 3: ReadWatt installed�Finally, connect the cable