4.7.- CONFIGURATION
In the setup menu you can:
Program the weight and type of impulse output
Program the communications.
Program the display screen.
Program the cost of the energy and the CO
2.
emissions
Partial energy meter deletion.
The standby mode is activated again when no button is pressed for 60 seconds.
Long press the button in the standby mode screen to open these setup screens. Short
press the button to display the home screen, Figure 12:
Figure 12: Home setup screen�
Long press the button to access the rst programming step.
4�7�1� Impulse output weight
This is the home screen for entering the weight of the impulse
output.
Long press the button to view the value to be programmed.
To write or modify the value, short press the button
repeatedly, increasing the value of the ashing digit.
When the desired value is shown on the screen, move onto the next digit with a long press on
the button, allowing the remaining values to be modied.
To validate the data, move to the last digit and long press the button; the validation screen
will appear (Figure 13) indicating that the programming value has been saved.