4�6�3�1�3� Scheduling time intervals in hours
If the CirLAMP Manager has the input and output module (M8I8O Expansion module) the
work intervals can be programmed automatically from Sunrise (Sunrise time).
Figure 20:Screen for scheduling time intervals in hours�
The parameters are:
Cnt: Node identier.
inTime: Interval 1 activation time. This parameter cannot be modied; it coincides
with the Sunrise value (Sunrise time).
power1: Power value in % during interval 1.
rstTime: Interval 2 activation time.
power2: Power value in % during interval 2.
secondTime: Interval 3 activation time.
power3: Power value in % during interval 3.
thirdTime: Interval 4 activation time.
power4: Power value in % during interval 4. Interval 4 will last until the node has
no power supply.
Click on the Send button to send the data to the unit.
Read access user: The programming of intervals in hours cannot be modied.