Circutor CIRLAMP Series Manual de usuario Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
 maxOrderOutdate: Window of time for the validation of orders, in seconds.
timeDelayRestart: Waiting time to continue the tasks, in seconds.
4.6.10.7. CirLamp remote management system conguration
Figure 66:CirLamp remote management system conguration.
On this screen, Figure 66, you can congure all the parameters for the CIRLamp telemanage-
ment system.
ipStg: IP address.
stgPwd: Password.
 stgPath: Path.
4�6�10�8� Communications interval
Figure 67:Conguration of the communications interval.
The nodes may not be on all day; for this reason, on this screen, Figure 67, the intervals for
communication between the nodes and the CirLAMP can be congured:
activeFilterTime, This parameter selects the communications interval; the three possible
options are:
Enable: A xed period of time is enabled to perform the communications. In this case,
the communications activation time is entered in hourini, and the end time in hourEnd.
Disable: There is no xed communications interval, the CirLAMP will try to communi-
cate with the nodes at any time, even if these are not connected.
NB: This option is not recommended if the nodes are stopped during the day.
Automatic: The CirLAMP will calculate sunrise and sunset using geolocation. The
parameters hourini and hourEnd are calculated automatically.
61
Instruction Manual
CirLAMP system
Vista de pagina 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 101 102

Comentarios a estos manuales

Sin comentarios