Circutor CIRLAMP Series Manual de usuario Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
Container element: < E13/L13>
< E13/L13> is the container element for information relating to the conguration of the unit's
inputs/outputs:
Table 56:File E13-L13, element <E13/L13>
Attribute Description
ActDate Order activation date.(E13)
Fh Report date. (read L13)
OffsetSunRise Length of deviation in minutes before activating
the output congured for sunrise.
OffsetSunSet Length of deviation in minutes before activating
the output congured for sunset.
Container element: < Input>
< Input> is the container element for information relating to the conguration of an input for the
unit:
Table 57:File E13-L13, element <Input>
Attribute Description
Dir Input direction.
Value Indicates whether the input is active (1: active, 0: inactive) (only in le
L13).
SponEnable Activates or deactivates the spontaneous event in the inputs.
Container element: < Output>
< Output> is the container element for information relating to the conguration of an output for
the unit:
Table 58:File E13-L13, element <Output>
Attribute Description
Dir Output direction
Sunset
Enables or disables the activation of the output during sunset.
(1: enabled, 0: disabled)
Sunrise
Enables or disables the activation of the output during sunrise.
(1: enabled, 0: disabled)
In1
Enables or disables the activation of the output via input 1. (1: ena-
bled, 0: disabled)
In2
Enables or disables the activation of the output via input 2. (1: ena-
bled, 0: disabled)
In3
Enables or disables the activation of the output via input 3. (1: ena-
bled, 0: disabled)
In4
Enables or disables the activation of the output via input 4. (1: ena-
bled, 0: disabled)
In5
Enables or disables the activation of the output via input 5. (1: ena-
bled, 0: disabled)
In6
Enables or disables the activation of the output via input 6. (1: ena-
bled, 0: disabled)
In7
Enables or disables the activation of the output via input 7. (1: ena-
bled, 0: disabled)
In8
Enables or disables the activation of the output via input 8. (1: ena-
bled, 0: disabled)