Circutor CIRLAMP Series Manual de usuario Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
Container element: < L07/E07>
< L07/E07> is the container element for information relating to alarm adjustment:
Table 36:File E07-L07, element <L07/E07>
Attribute Description
ActDate Order activation date.
Container element: < Node>
< Node> is the container element for information relating to a node:
Table 37:File E07-L07, element <Node>
Attribute Description
nodeId Node identier.
Container element: < Alarms>
<Alarms> is the container element for information relating to the adjustment of a node's
alarms:
Table 38:File E07-L07, element <Interval>
Attribute Description
blinkActive Threshold of active power for the intermittent bulb alarm.
blinkTime
Blinking time for the intermittent bulb alarm (seconds).
blinkTimes
Number of blinks for the intermittent bulb alarm.
blinkTotalTime
Total blinking time for the intermittent bulb alarm (seconds).
brokenActive
Threshold of active power for the burnt out lamp alarm.
brokenTime
Alarm time for the burnt out lamp (seconds).
capacitorReactive
Threshold of reactive power for the broken capacitor alarm.
capacitorTime
Broken capacitor alarm time (seconds).
powerLamp
Lamp power
timeAlarm
Alarm detection time (seconds).
percentageAlarm
Minimum percentage to detect the alarm.
factorPower
Minimum power factor to detect the alarm.
4�6�4�8� E08-L08, Delete nodes from the network
Format of le E08 (Figure 39):
<Order IdReq=”E08” IdPet=”2” Version=”3�0”>
<CirLamp Id=”CIR0000001”>
<E08 ActDate=”20121114165000000W”>
<Node nodeId=”2000002”/>
</E08>
</CirLamp>
</Order>
Figure 39: File E08�