In the EDA Flat rate mode, the customer can consume an average amount of EDA units which
is pre-dened and limited by the contracted power.
If the energy daily allowance has not been consumed, it can be stored in the EDA tank up to its
nominal capacity, which has been previously programmed in the card.
Unlike type 3 contracts, the customer pays for the days of service and when these end, the
customer must purchase additional days of service from the DISPENSER-SOFT operator.
The supply is cut off after this period.
If the EDA balance is used up and the tank is filled after activating the dripping option, the gen-
eral relay will be automatically rearmed, following a reclosing sequence that varies according
to the times the power supply has been cut off during the day (See 5.2.4.1.- GENERAL RELAY).
This type of contract can have no denite time limit, Open-ended contract, with no additional
costs included in the price of energy. Designed for buildings that are not charged for the use
of energy, such as cultural centres, churches, etc.