Type 2 Contract:
Figure 50:Create a new tariff (Tariff conditions - Type 2 Contract)
Table 12:Create a new tariff (Tariff Conditions: Base Parameters)
Base Parameters
Parameter Description Range of values
Power base
(5)
Base power of the customer 100 ... 1000 W
Power multiplier
(5)
Multiplier of the base power 1 ...100
(5)
The Contracted power = Base power x Power multiplier
The price of energy and contracted power are xed values that can vary according to the differ-
ent factors applied:
Excess and limiting factor of contracted power (See 3.3.- CONTROLLING THE MAX-
IMUM POWER)
Bonus and restriction factors applied to the price of energy. (See 3.2.- ENERGY FAC-
TORS)
Table 13:Create a new tariff (Tariff Conditions: Denition of factors)
Denition of factors
Parameter Description Range of values
Coefcients of contrated power
Excess
Factor that increases the maximum power of the in-
stallation when the micro-grid is in the bonus mode.
1 ...3
Limitation
Factor that decreases the maximum power of the
installation when the micro-grid is in the restriction
mode
0 ... 1
Coefcients of energy price
Bonus
Factor to reduce the price of energy when the mi-
cro-grid is in the bonus mode
0.4 ... 1
Restriction
Factor to increase the price of energy when the mi-
cro-grid is in the bonus mode
1.2 ... 3